Additional technical information: Design: 17121Core number/cross-section: 8à 0.25 mm²Drag chain values: 5 Mio.Wire insulation: PP (ws, br, gn, ge, gr, rs, bl, rt)Bending radius (moving): 10à outer-ÃTemperature range (flexible): -25...+80 °C.Cable identification 291Cable weight [g/m]: 78.10Material (conductor): Plain copper braidResistance (conductor): Max. 79 â¦/km (20 °C)Single wire à (conductor): 0.1 mmConstruction (conductor): 32à 0.1 mm (strand class 6)AWG: Similar AWG 24Material (core insulation): PPWire à incl. insulation: 1.2 mm ±5%Wire color/numbering: br, ws, rt, bl, rs, gr, ge, gnVerseilverbund: 8 cores stranded around core fillerShielding: yesChemical resistance: Good resistance to oil, petrol and chemicals (EN 60811-404)Thermal resistance: Flame-resistant according to UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2Test voltage: 2000 V/ACBending radius (fixed): 5à outer-ÃNumber of bending cycles (drag chain): Max. 5 Mio (25 °C)Travel path (drag chain): Max. 5 m (horizontal)Travel speed (drag chain): Max. 3.3 m/s.Acceleration (drag chain): Max. 5 m/s²Locking the slots: Screw thread (M12Ã1 mm) recommended tightening torque 0.6 Nm, self-lockingMaterial (lock): Stainless steel 1.4305 (V2A)Pollution level 3; Cable colour: Grey; Cable diameter: 7.0 mm; Cable length: 10.00 m; Coding: A; Connection side A (sensors/actuators): M12 socket, straight; Connection side B (sensors/actuators): Cable, open end; Cross-section (sensor/actuator wiring): 0.25 mm²; IP rating: IP66K, IP67 (when connected); Jacket material: PUR; Max. temperature: +80 °C; Min. temperature: -40 °C; Nominal current: 2 A; Nominal voltage: 300 V AC; Outside diameter: 7.0 mm; Thread type (wiring and installation): M12